Apc surt 20000 UPS Schneider uninteruptable power supply 16Kw 20kva SURT20KRMXLI

Apc surt 20000 UPS Schneider uninteruptable power supply 16Kw 20kva SURT20KRMXLI

Apc surt 20000 UPS Schneider uninteruptable power supply 16Kw 20kva SURT20KRMXLI

Apc surt 20000 UPS Schneider uninteruptable power supply 16Kw 20kva SURT20KRMXLI

Apc surt 20000 UPS Schneider uninteruptable power supply 16Kw 20kva SURT20KRMXLI

Apc surt 20000 UPS Schneider uninteruptable power supply 16Kw 20kva SURT20KRMXLI

Apc surt 20000 UPS Schneider uninteruptable power supply 16Kw 20kva SURT20KRMXLI

Apc surt 20000 UPS Schneider uninteruptable power supply 16Kw 20kva SURT20KRMXLI

Apc surt 20000 UPS Schneider uninteruptable power supply 16Kw 20kva SURT20KRMXLI

Apc surt 20000 UPS Schneider uninteruptable power supply 16Kw 20kva SURT20KRMXLI

Apc surt 20000 UPS Schneider uninteruptable power supply 16Kw 20kva SURT20KRMXLI

Apc surt 20000 UPS Schneider uninteruptable power supply 16Kw 20kva SURT20KRMXLI

Apc surt 20000 UPS Schneider uninteruptable power supply 16Kw 20kva SURT20KRMXLI

Apc surt 20000 UPS Schneider uninteruptable power supply 16Kw 20kva SURT20KRMXLI   Apc surt 20000 UPS Schneider uninteruptable power supply 16Kw 20kva SURT20KRMXLI

APC Smart-UPS RT 20kVA RM 230V. The ups has an AP9631 network management card pre installed and is fitted with a mains lead connected to a 16amp plug Please note this mains lead and plug is only suitable for use at low loads as it was only fitted for test purposes so you really should remove this and hard wire directly to a suitable high current supply with suitable cable.
Increases availability by allowing the UPS to be connected to two separate power sources. Alpha-Numeric Display which displays system parameters and alarms.

Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime. Protects the initial investment in the UPS when migrating from tower to rack-mount environment. Allows quick and easy installation and maintenance of the UPS.

Single or three-phase input wireable. Provides flexibility for the UPS to be installed using either single or three-phase input wiring. Install maintenance releases of firmware remotely using FTP. Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Provides notification of changing utility power and UPS power conditions. Warns when a battery is not available to provide backup power. Provides early-warning fault analysis ensuring proactive component replacement.
Periodic battery self-test ensures early detection of a battery that needs to be replaced. Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR). Provides temporary battery power when the utility power is out. Ensures clean, uninterrupted power to protected equipment when generator power is used. Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Easy recovery from overloads; no need to replace a fuse. Minimizes installation costs by enabling the use of smaller generators and cabling. Gives higher application availability by correcting poor frequency and voltage conditions without using the battery. Protects connected loads from surges, spikes, lightning, and other power disturbances. Low operating and maintenance costs with proven reliability and intelligent battery management.

Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down. Avoids costly power problems by keeping your IT equipment and data protected and available. Network grade power conditioning protects from damaging surges and disruptive noise.

The double conversion architecture provides tight voltage regulation, frequency regulation , and zero transfer time to battery during power events. Peace of mind that comes with full equipment compatibility and reliability of a leader. Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industrys most rigorous standards. Save time with easy and convenient remote accessibility.

Network manageable via serial, USB or optional Ethernet. Includes Powerchute® Network Shutdown Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities. Enables centralized management via the APC InfraStruXure Manager. Provides remote power management of the UPS over the network. Customize UPS capabilities with management cards.

Quickly understand unit and power status with visual indicators. Provides management of the UPS via a serial port.
Prolongs battery life by regulating the charge voltage according to battery temperature. Automatic restart of loads after UPS shutdown. Automatically starts up the connected equipment upon the return of utility power.

Supplies utility power to the connected loads in the event of a UPS power overload or fault. Allows additional run time to be quickly added as needed. Ensures clean, uninterrupted power to protected equipment while batteries are being replaced. Maximizes battery performance, life, and reliability through intelligent, precision charging.

16.0 KWatts / 20.0 kVA. Configurable for 400 or 415V 3 Phase nominal output voltage.
Output Frequency (sync to mains). 50/60 Hz +/- 3 Hz user adjustable +/- 0.1. (2) IEC Jumpers (Battery Backup). (8) IEC 320 C19 (Battery Backup). (1) Hard Wire 3-wire (H N + G) (Battery Backup).
Built-in Static Bypass, Internal Bypass (Automatic and Manual), Optional External Bypass. 40 - 70 Hz (auto sensing). Hard Wire 3 wire (1PH+N+G), Hard Wire 5-wire (3PH + N + G).
Input voltage range for main operations. Less than 5% for full load. Input Power Factor at Full Load. Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof. +/-192 V (split battery referenced to neutral). End of Discharge Battery Voltage. DB-9 RS-232 , RJ-45 10/100 Base-T , Smart-Slot. Multi-function LCD status and control console. Audible and visible alarms : configurable delays. Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449. 0 - 95% non-condensing %. Audible noise at 1 meter from surface of unit. BSMI, EN/IEC 62040-2, EN/IEC 62040-1-1, VDE. 2 years repair or replace. The item "Apc surt 20000 UPS Schneider uninteruptable power supply 16Kw 20kva SURT20KRMXLI" is in sale since Tuesday, October 31, 2017. This item is in the category "Computers/Tablets & Networking\Power Protection, Distribution\Uninterruptible Power Supplies". The seller is "iancewers" and is located in bicester, Oxfordshire. This item can be shipped to United Kingdom.
  • Type: Enterprise/Data Center UPS
  • Brand: APC
  • Model: SURT20KRMXLI
  • Max. Wattage: 16000 W
  • Voltage Compatibility: 220V
  • MPN: SURT20KRMXLI
  • Features: Audible Alarm
  • Number of Outlets: 8